Diversatek ComforTEC Z/pH Probes ZepHr Recorder with Reflux Probe Zephr Recorder Cover ZepHr Sphincter Locator

For optimal performance, trust Impedance/pH Probes manufactured only by Diversatek Healthcare.

ComforTEC Z/pH and pH Probes

Diversatek ComforTEC Z/pH Probes
ZepHr Recorder with Reflux Probe
Zephr Recorder Cover
ZepHr Sphincter Locator

For optimal performance, trust Impedance/pH Probes manufactured only by Diversatek Healthcare.

Comfortable, Easy, Smooth and Flexible

Reflux Probes from Diversatek Healthcare are the perfect choice for every application. Our Impedance/pH and pH Probes are available in three sizes to meet a variety of esophageal lengths. Small in diameter, our probes are made from specially formulated polyurethane, which softens in response to body temperature to optimize ease of insertion and enhance patient comfort.

 

Performance in Total Reflux Monitoring

The ZepHr® Reflux Monitoring System employs impedance to detect reflux activity and uses pH and impedance to categorize each episode as acid or nonacid. We call this unprecedented breakthrough Total Reflux Monitoring, because it delivers all the information you need for a precise, accurate assessment of acid and nonacid reflux as well as the correlation between reflux and symptoms.

ComforTEC Z/pH Probes: Internal Reference, Non-infused.

Part No. Description Unit
ZAN-BS-01 ≥ 18 cm Esophageal length, 6 impedance, 1 pH channel (esophageal), 6.4 FR / 2.13 mm Each
ZAN-BD-31
Part No. Description Unit
ZAN-BD-31 ≥ 18 cm Esophageal length, 6 impedance, 2 pH channels 0 & 15 cm (esophageal), 6.4 FR / 2.13 mm Each
ComforTEC-ZAN-BG-44
Part No. Description Unit
ZAN-BG-44 ≥ 18 cm Esophageal length, 6 impedance, 2 pH channels -15 & 0 cm (esophageal and gastric), 6.4 FR / 2.13 mm Each
ComforTEC-ZPN-BG-07
Part No. Description Unit
ZPN-BG-07 15–18 cm Esophageal length, 6 impedance, 2 pH channels -12 & 0 cm (esophageal and gastric), 6.4 FR / 2.13 mm Each
ComforTEC-ZPN-BS-46
Part No. Description Unit
ZPN-BS-46 15–18 cm Esophageal length, 6 impedance, 1 pH channel (esophageal), 6.4 FR / 2.13 mm Each
ComforTEC-ZPN-BS-50
Part No. Description Unit
ZPN-BS-50 15–18 cm Esophageal length, 6 impedance, 1 pH channel (esophageal), 6.4 FR / 2.13 mm Each
ZPN-BG-57
Part No. Description Unit
ZPN-BG-57 15–18 cm Esophageal length, 6 impedance, 2 pH channels -7 & 0 cm (esophageal and gastric), 6.4 FR / 2.13 mm Each
ComforTEC-ZIN-BS-51
Part No. Description Unit
ZIN-BS-51 < 15 cm Esophageal length, 6 impedance, 1 pH channel (esophageal), 6.4 FR / 2.13 mm Each

ComforTEC Z/pH Probes: Internal Reference, Infused.

ComforTEC-ZAI-BS-01
Part No. Description Unit
ZAI-BS-01 ≥ 18 cm Esophageal length, 6 impedance, 1 pH channel (esophageal), infusion port at 6 cm, 6.9 FR / 2.3 mm Each
ComforTEC-ZAI-BD-31
Part No. Description Unit
ZAI-BD-31 ≥ 18 cm Esophageal length, 6 impedance, 2 pH channels 0 & 15 cm (esophageal), infusion port at 6 cm, 6.9 FR / 2.3 mm Each
ComforTEC-ZAI-BG-44
Part No. Description Unit
ZAI-BG-44 ≥ 18 cm Esophageal length, 6 impedance, 2 pH channels -15 & 0 cm (esophageal and gastric), infusion port at 6 cm, 6.9 FR / 2.3 mm Each
ComforTEC-ZPI-BS-46
Part No. Description Unit
ZPI-BS-46 15–18 cm Esophageal length, 6 impedance, 1 pH channel (esophageal), infusion port at 6 cm, 6.9 FR / 2.3 mm Each
ComforTEC-ZPI-BG-52
Part No. Description Unit
ZPI-BG-52 15–18 cm Esophageal length, 6 impedance, 2 pH channels -12 & 0 cm (esophageal and gastric), infusion port at 6 cm, 6.9 FR / 2.3 mm Each

ComforTEC LPR Probes: Internal Reference, Infused.

ComforTEC-ZAI-BL-54
Part No. Description Unit
ZAI-BL-54 26–28 cm Esophageal length, 2 pH channels -25 & 0 cm (UES), infusion port at 6 cm (above UES), 6.9 FR / 2.3 mm Each
ComforTEC-ZAI-BL-55
Part No. Description Unit
ZAI-BL-55 23–25 cm Esophageal length, 2 pH channels -22 & 0 cm (UES), infusion port at 6 cm (above UES), 6.9 FR / 2.3 mm Each
ComforTEC-ZAI-BL-56
Part No. Description Unit
ZAI-BL-56 20–22 cm Esophageal length, 2 pH channels -19 & 0 cm (UES), infusion port at 6 cm (above UES), 6.9 FR / 2.3 mm Each

ComforTEC Z/pH Probe. External Reference, Non-infused.

ZAN-BS-01E
Part No. Description Unit
ZAN-BS-01E ≥ 18 cm Esophageal length, 6 impedance, 1 pH channel (esophageal), 6.4 FR / 2.13 mm Each
ZPN-BS-46E
Part No. Description Unit
ZPN-BS-46E 15–18 cm Esophageal length, 6 impedance, 1 pH channel (esophageal), 6.4 FR / 2.13 mm Each
ZIN-BS-45E
Part No. Description Unit
ZIN-BS-45E < 15 cm Esophageal length, 6 impedance, 1 pH channel (esophageal), 6.4 FR / 2.13 mm Each

ComforTEC PLUS pH Probe. Internal Reference, Non-infused.

PHNS-P
Part No. Description Unit
PHNS-P 1 pH channel, 5 FR / 1.67 mm Each
PHNS
Part No. Description Unit
PHNS 1 pH channel, 6.4 FR / 2.13 mm Each
PHN5
Part No. Description Unit
PHN5 2 pH channels 0 & 5 cm, 6.4 FR / 2.13 mm Each
PHN10-P
Part No. Description Unit
PHN10-P 2 pH channels 0 & 10 cm, 5 FR / 1.67 mm Each
PHN10
Part No. Description Unit
PHN10 2 pH channels 0 & 10 cm, 6.4 FR / 2.13 mm Each
PHN15
Part No. Description Unit
PHN15 2 pH channels 0 & 15 cm, 6.4 FR / 2.13 mm Each
PHN21
Part No. Description Unit
PHN21 2 pH channels 0 & 21 cm, 6.4 FR / 2.13 mm Each

ComforTEC PLUS p/H Probe. Internal Reference, Infused.

PHIS
Part No. Description Unit
PHIS 1 pH channel, infusion port at 5 cm, 6.9 FR / 2.3 mm Each
PHI10
Part No. Description Unit
PHI10 2 pH channels 0 & 10 cm, infusion port at 5 cm, 6.9 FR / 2.3 mm Each
PHI15
Part No. Description Unit
PHI15 2 pH channels 0 & 15 cm, infusion port at 5 cm, 6.9 FR / 2.3 mm Each
Contact us at
sales@diversatekhc.com
800.558.6408 or 414.265.7620

Product Attributes

  • The widest range of standard probe configurations to meet your clinical needs for impedance/pH and pH-only studies
  • Multiple sensor configurations available to accommodate a variety of study requirements and esophageal lengths
  • Specially-formulated polyurethane, which softens in response to body temperature, optimizing ease of insertion and enhancing patient comfort enhancing
  • Three probe sizes to detect full column and laryngopharyngeal reflux with positioning bands for precise placement just above the the UES when a prior manometry study is no available
  • Single-use, Non-sterile